All
  • All
  • Product Management
  • News
  • Introduction
  • Enterprise outlets
  • FAQ
  • Enterprise Video
  • Enterprise Atlas

Product name: EMT220 Vibration Meter

Views:

Goods ID: 15485169

  • Introduction
  • Parameter
  •  


    Details:

    • Vibration transducer:

    Integral, annular shear type acceleration transducer (only for integral type)Separate, built-in electric charge amplifier, shear type acceleration transducer (only for separate type)

     • Temperature transducer:

    Type K thermoelectro couple transducer (only for EMT220 with temperature measuring function)

    • Detector:

    Root Mean Square

    • Vibration measurement scale:

     Displacement: 0.0011.999 mm (peak to peak)
     Velocity: 0.01
    19.99 cm/s (r.m.s. value)
     Acceleration: 0.1
    199.9 m/s2 (peak value)
     Vibration acceleration: ≤ 199.9 m/s2 (peak value)


    • Temperature measurement scale: 

     -20 400 (only for EMT220 with temperature-measuring
     function)


    • Accuracy:

      Vibration measurement: ±5Measurement value; ±2 Digits
      Temperature measurement: ±1% Measurement value; ±1 Digit


    Vibration Frequency Range:

      10 1 kHz (Normal type)
      5
    1 kHz (Low frequency type)
      1
    15 kHz (only at “HI” position for acceleration)

    • Display: Digits liquid crystal display

    • Sample period:1 second

    • Vibration measurement value readout:

      Displacement: Peak to peak value (r.m.s.×2√2)
      Velocity: Root mean square (r.m.s.)
      Acceleration: Peak value (r.m.s.x√2)


    • Readout-keeping function:

      Readout of vibration / temperature value can be remembered after
      releasing the Measure Key (Vibration / Temperature Switch)


    • Output Signal:

    2V AC (peak value) (load resistance above 10 kΩ at full measuring scale)

    • Power supply:

    6F22 9V laminated cell

    • Power on / off:

      Battery life about 30 hours for continuous use
      Power up when pressing Measure Key (Vibration / Temperature Switch)
      Power automatically shut off after releasing the Measure Key for one minute


    • Operating condition:

     Temperature: 0 50  
      Humidity: ≤ 90% RH


    • Volume:

    185 mm×68 mm×30 mm

    • Weight:200g